Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

Stove Fitting and Approved Document J in Drawings The Same Order on Every Job

For England and Wales. Hearths, clearances to combustibles, air supply, flue pipe and liners, register plates, twin-wall, terminals, CO alarms and commissioning. Every topic has its own page: the drawing first, then the numbers to have to hand. 65 illustrated pages.

START FITTING THIS WAY

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageEach rule drawn, with the explanation alongside
65 illustrated pages9 parts, from how a stove and chimney work together to the job checklist from survey to handover
Up-to-date sourcesApproved Document J, BS EN 15287-1 and BS EN 50291-1
PDF by emailFormat

Look Inside the Book

Every page has one large drawing and a box with the measurements and rules you need to know:

8 kW stove, leaky house: (8 − 5) × 550 = 1,650 mm² free area.
8 kW stove, leaky house: (8 − 5) × 550 = 1,650 mm² free area.
Leaky house, with stabiliser, 8 kW: 5 × 300 + 3 × 850 = 4,050 mm².
Leaky house, with stabiliser, 8 kW: 5 × 300 + 3 × 850 = 4,050 mm².
125 mm for smokeless fuel up to 20 kW, 150 mm for any fuel up to 30 kW
125 mm for smokeless fuel up to 20 kW, 150 mm for any fuel up to 30 kW
Firestop at each ceiling, G-mark gap all round, supports to the manual.
Firestop at each ceiling, G-mark gap all round, supports to the manual.
Cowls don't count towards height and mustn't block sweeping.
Cowls don't count towards height and mustn't block sweeping.
Commissioning: sweep or coring ball, smoke test, spillage test on a warm flue
Commissioning: sweep or coring ball, smoke test, spillage test on a warm flue
125 mm, 840 × 840 mm, 3 × D, 550 mm² per kW, 4.5 m, 600 mm, 1–3 m
125 mm, 840 × 840 mm, 3 × D, 550 mm² per kW, 4.5 m, 600 mm, 1–3 m
A tick-box list: smoke test, hearth, vent, liner, terminal, CO alarm, notice plate, certificate
A tick-box list: smoke test, hearth, vent, liner, terminal, CO alarm, notice plate, certificate

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 9 parts and 61 topics.

The Problem Isn't You. It's How It Was Explained to You.

The stove has a rear outlet, there's a beam in the way and you're planning the pipe run on site. The customer asks if it'll still draw properly.

You know there's a limit on bends. But it's buried in a paragraph, and on site you can't remember whether the tee at the outlet counts.

125 mm for smokeless fuel up to 20 kW, 150 mm for any fuel up to 30 kW

In the book, bends and horizontal runs are one drawn page: the pipe run from stove to chimney with every angle marked, a maximum of four bends at 45° from vertical, and a 90° tee at the outlet counted as two.

The hearth, the vent size, the terminal near the ridge, the CO alarm and the spillage test each get their own page too.

You look at the run, count the bends and plan the job without opening the manual again.

COMPARE FOR YOURSELF

The Same Topic, Two Ways to Learn It

THIS
  • The manual: line after line of text
  • Vent sizes explained only in words
  • You get to the job still unsure
Where a draught stabiliser is fitted to a solid fuel appliance installed in a dwelling, the provision for permanently open ventilation shall be increased accordingly. In dwellings with a design air permeability exceeding the stated threshold, the free area required shall be calculated at 300 mm² per kW for the first 5 kW of rated output and at 850 mm² per kW for the balance thereof, whereas in dwellings of lower permeability the higher rate shall apply to the total rated output of the appliance.
FOR THIS
  • The stabiliser sum in one drawing
  • The figures in one box
  • You see it and you get it
Leaky house, with stabiliser, 8 kW: 5 × 300 + 3 × 850 = 4,050 mm².
CONTENTS

Take a Look at the 9 Parts and 61 Topics

How a stove and chimney work, the survey, the hearth, clearances, air supply, flue pipe and liners, twin-wall and terminals, commissioning and the on-site review: 65 pages, all illustrated

IHow a Stove and Chimney Work Together · pp. 5-10
  1. One System, Not Two Parts
  2. What Draught Really Is
  3. Closed Appliance vs Open Fire
  4. Wood, Multi-Fuel and Smokeless Fuel
  5. Rated Output and Why Every Sum Starts There
  6. The Job in the Same Order Every Time
IISurvey Before You Quote · pp. 11-17
  1. What Approved Document J Covers
  2. Notifying the Work
  3. Smoke Control Areas
  4. Ecodesign and Ready to Burn
  5. Inspecting an Existing Chimney
  6. The Smoke Pellet Test on the Old Flue
  7. Measuring the Room and Fireplace
IIIThe Hearth · pp. 18-24
  1. Constructional vs Superimposed Hearth
  2. Hearth Size for a Freestanding Stove
  3. Hearth Inside a Fireplace Recess
  4. Space Around the Stove on the Hearth
  5. When a 12 mm Hearth Is Enough
  6. Timber Floors Under the Hearth
  7. Marking the Hearth Edge
IVClearances to Combustibles · pp. 25-31
  1. Manufacturer's Clearances Come First
  2. Walls Next to the Hearth
  3. The Single-Wall Pipe Rule: 3 × Diameter
  4. Shields Cut the Distance to 1.5 × Diameter
  5. The Oak Beam Over the Fireplace
  6. Masonry Chimney: 200 mm or 40 mm
  7. Twin-Wall Clearance Markings
VAir Supply · pp. 32-37
  1. Why a Stove Needs Air From Outside
  2. The 5 kW Rule and 550 mm² per kW
  3. Worked Example: an 8 kW Stove
  4. Airtight Houses and New Builds
  5. Draught Stabilisers Change the Sum
  6. Where the Vent Goes
VIFlue Pipe, Liners and Register Plates · pp. 38-46
  1. Minimum Flue Size
  2. Flue Height: at Least 4.5 m
  3. Bends and Horizontal Runs
  4. Connecting Pipe Rules
  5. Choosing a Flexible Liner
  6. Fitting the Liner in Stages
  7. The Register Plate
  8. Rear vs Top Outlet
  9. Masonry Flue Without a Liner
VIITwin-Wall Systems and Terminals · pp. 47-52
  1. When to Use an Insulated Twin-Wall Chimney
  2. Through the Ceiling and Loft
  3. Terminal Height Near the Ridge
  4. Terminal Height on a Roof Slope
  5. Windows, Roof Lights and Neighbours
  6. Cowls, Caps and Bird Guards
VIIICommissioning and Handover · pp. 53-59
  1. The CO Alarm Rule
  2. Where the CO Alarm Goes
  3. Commissioning Fire and Spillage Check
  4. Measuring Draught
  5. The Notice Plate
  6. What the Customer Must Be Left With
  7. Talking the Customer Through the First Burn
IXOn-Site Review: Faults, Mistakes and Checklist · pp. 60-65
  1. Smoke Into the Room: Where to Start
  2. Poor Draught on a Warm Flue
  3. Tar, Creosote and Glass Blackening
  4. The Mistakes Seen Most Often
  5. The Numbers to Have to Hand
  6. Job Checklist From Survey to Handover

One Page, One Topic, All Clear

Think of it like this:

You're on a survey. An 8 kW stove, an older, draughty house, and the customer asks how big the air vent in the wall has to be.

You open the air supply page and see the sum drawn step by step: the first 5 kW without a vent, then 550 mm² for every kW above: (8 − 5) × 550 = 1,650 mm².

Cowls don't count towards height and mustn't block sweeping.

The same goes for the hearth, the oak beam over the fireplace, the liner fitted in stages, the terminal near the ridge and the CO alarm: each one on its own page.

Stove Fitting Illustrated is 65 illustrated pages in 9 parts, one drawn topic per page, ending with the numbers to have to hand and a job checklist from survey to handover.

What you see drawn, you don't have to memorize.

What's Inside Stove Fitting Illustrated:

Ipp. 5-10

How a Stove and Chimney Work Together

The stove and chimney as one system, what draught really is, closed appliance vs open fire, wood, multi-fuel and smokeless fuel, rated output and the job in the same order every time.

IIpp. 11-17

Survey Before You Quote

What Approved Document J covers, notifying the work, smoke control areas, Ecodesign and Ready to Burn, inspecting an old chimney, the smoke pellet test and measuring the room.

IIIpp. 18-24

The Hearth

Constructional vs superimposed hearths, hearth size for a freestanding stove, hearths in a recess, space around the stove, the 12 mm hearth, timber floors and marking the edge.

IVpp. 25-31

Clearances to Combustibles

Manufacturer's clearances first, walls next to the hearth, the 3 × diameter pipe rule, shields, the oak beam, masonry chimney distances and twin-wall markings.

Vpp. 32-37

Air Supply

Why a stove needs outside air, the 5 kW rule and 550 mm² per kW, a worked 8 kW example, airtight houses, draught stabilisers and where the vent goes.

VIpp. 38-46

Flue Pipe, Liners and Register Plates

Minimum flue size, the 4.5 m height, bends and horizontal runs, connecting pipe, choosing and fitting a flexible liner, the register plate, rear vs top outlet and unlined masonry flues.

VIIpp. 47-52

Twin-Wall Systems and Terminals

When to use insulated twin-wall, going through ceiling and loft, terminal height near the ridge and on a slope, windows and neighbours, cowls, caps and bird guards.

VIIIpp. 53-59

Commissioning and Handover

The CO alarm rule and where it goes, the commissioning fire and spillage check, measuring draught, the notice plate, what the customer must be left with and the first burn.

IXpp. 60-65

On-Site Review: Faults, Mistakes and Checklist

Smoke into the room, poor draught on a warm flue, tar and glass blackening, the most frequent mistakes, the numbers to have to hand and the job checklist.

At the end of the book: The numbers to have to hand on one page and a tick-box job checklist from survey to handover.

Plus: 2 Free Books

Stove Fitting Worked Examples: Hearths, Vents and Clearances

BONUS 1: «Stove Fitting Worked Examples: Hearths, Vents and Clearances»

Value on its own: US$ 17.90

Practise the sums you do on every job — hearth size, vent size, distances to combustibles — on real-style rooms, with the answer drawn on the next page.

15 Stove Fitting Mistakes, Before and After

BONUS 2: «15 Stove Fitting Mistakes, Before and After»

Value on its own: US$ 14.90

See the 15 most common installation mistakes drawn wrong and then right, so you spot them before the customer or the inspector does.

Stove Fitting Illustrated with 2 Free Books

  • Stove Fitting Illustrated: 65 illustrated pagesUS$ 63
  • BONUS 1: Stove Fitting Worked Examples: Hearths, Vents and ClearancesUS$ 17.90
  • BONUS 2: 15 Stove Fitting Mistakes, Before and AfterUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 95.80
YOUR PRICE:
US$ 27
You save US$ 68.80
YES, I WANT STOVE FITTING ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Stove Fitting Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're booked on a solid fuel installer course

You're booked on a solid fuel installer course

Sweep or builder, you arrive with the whole install already in one order, survey to handover, each step drawn on its own page.

You've got an install booked

You've got an install booked

Before the job you check the hearth size, the vent sum and the terminal height at a glance, and turn up with the numbers to hand.

You already fit stoves

You already fit stoves

You keep it printed in the van: when the spillage test fails or the customer asks why, you open the page and show them.

Everything You Get Today

US$ 95.80US$ 27
YES, I WANT STOVE FITTING ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Stove Fitting Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I've been fitting stoves for years?

Yes. It isn't a beginner's course: it puts the whole job in one order with the numbers drawn, so you find the hearth, vent or terminal rule at a glance and can show it to the customer. It suits sweeps and builders taking on installs too.

Where does the content come from?

From the Approved Document J in force in England and the Welsh Approved Document J, BS EN 15287-1 for chimneys, BS EN 50291-1 for CO alarms, Defra smoke control area guidance and the Ecodesign rules for stoves sold since January 2022. Distances to combustibles always defer to the manufacturer's instructions. It's written for England and Wales only: Scotland and Northern Ireland have their own regulations, so it isn't meant for jobs there.

Is it official material?

No. It's an independent illustrated guide, not published or endorsed by any government department, standards body or competent person scheme. It doesn't give you a certificate or a qualification, and it doesn't let you self-certify work.

Does it replace training or a competent person scheme?

No. It's a reference to study and keep in the van. It doesn't replace training, the manufacturer's instructions or notifying the work through building control or a competent person scheme.

Are the practice examples taken from an official assessment?

No. The worked examples and the mistakes are written for this book. They aren't questions from any official assessment.

When and how do I get it?

The book and the 2 bonus books arrive in PDF by email, at the address you enter at checkout.

Do I have to pay every month?

No. It's a one-off payment, with no subscription.

Can I have it on paper?

Yes. The PDF prints on A4 at home or at a print shop, so you can keep it in the van.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading without it sticking.

The hearth, the vent and the bends: you see them drawn, and that's it.

You get to every job knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 27 · Guarantee: 30 days · PDF by email

YES, I WANT STOVE FITTING ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.